Standard Operating Procedure for Stability Chamber Management

Standard Operating Procedure (SOP) for Stability Chamber Management

1.0 Purpose:

To outline the procedures for the proper management and operation of stability chambers to ensure accurate and reliable stability testing of products.

2.0 Scope:

This SOP applies to all personnel involved in the operation, maintenance, and monitoring of stability chambers at [Company Name].

3.0 Responsibilities:

  • Quality Assurance Manager: Overall responsibility for ensuring compliance with this SOP.
  • Laboratory Technicians: Responsible for the daily operation and monitoring of stability chambers.
  • Facility Manager: Responsible for the maintenance and calibration of stability chambers.

4.0 Equipment:

  • Stability chambers (with temperature and humidity control)
  • Data logging system
  • Calibration equipment
  • Temperature and humidity sensors

5.0 Procedure:

5.1 Chamber Setup:

  • Ensure the stability chamber is clean and free from any residues before starting.
  • Verify that the chamber is calibrated and operating within specified temperature and humidity ranges.
  • Place temperature and humidity sensors at appropriate locations within the chamber.

5.2 Sample Preparation:

  • Prepare samples according to the established protocols.
  • Label each sample with a unique identifier, including the date of placement into the stability chamber.

5.3 Chamber Operation:

  • Load samples into the stability chamber according to the established storage conditions.
  • Record the start date and time of the stability study.
  • Close the chamber door securely to prevent temperature and humidity fluctuations.
  • Set the desired temperature and humidity conditions based on the study requirements.
  • Activate the data logging system to continuously monitor chamber conditions.

5.4 Monitoring and Maintenance:

  • Regularly monitor temperature and humidity levels within the stability chamber.
  • Perform daily visual inspections to ensure proper functioning of the chamber.
  • Calibrate temperature and humidity sensors as per the calibration schedule.
  • Clean the chamber interior regularly to prevent contamination.

5.5 Data Recording and Analysis:

  • Record temperature and humidity data at regular intervals as per the study protocol.
  • Store all data in a secure location for future reference and analysis.
  • Analyze stability data to assess the product’s shelf life and degradation profile.

5.6 Deviations and Corrective Actions:

  • In case of any deviations from the established procedures, immediately notify the Quality Assurance Manager.
  • Investigate the root cause of the deviation and implement corrective actions to prevent recurrence.
  • Document all deviations and corrective actions in the deviation log.

6.0 Documentation:

  • Maintain accurate records of stability chamber operation, including calibration certificates, temperature/humidity logs, and maintenance records.
  • Ensure all documentation is stored in a secure and accessible manner.

7.0 Training:

  • Provide training to personnel involved in stability chamber management on the proper procedures outlined in this SOP.
  • Conduct periodic refresher training to ensure compliance with the SOP.

8.0 References:

  • Relevant regulatory guidelines
  • Manufacturer’s instructions for stability chamber operation and maintenance

9.0 Revision History:

  • Document all revisions made to this SOP with dates and reasons for the change.

10.0 Approval:

  • This SOP must be approved by the Quality Assurance Manager before implementation.

11.0 Distribution:

  • Ensure all personnel involved in stability chamber management have access to the latest version of this SOP.

12.0 Compliance:

  • Failure to comply with this SOP may result in product quality issues and regulatory non-compliance.

13.0 Abbreviations:

  • List any abbreviations used throughout the SOP for clarity.

Leave a Comment